Description
APPLICATIONS
Double walled Horizontal Autoclaves are most ideal for critical applications requiring assured and reliable total destruction of all living micro- organisms It is based on the principle that microbiological action of saturated steam at elevated temperature is rapid and through.
Autoclave Horizontal is low cost options for general sterilization ideal tool for Laboratories, Hospitals, Nursing Homes, Agricultural R&D labs etc, Pharmaceutical, Food & Beverage Industries and Institutions.
Suitable for Sterilizing hospital dressings, linen, rubber, plastic goods, surgical instruments, glasswares, utensils etc.
SALIENT FEATURES & CONSTRUCTION
Double walled unit horizontally mounted on a sturdy, heavy M.S. duly painted or Stainless steel tubular stand.
Chamber & Boiler (Steam Generator) are constructed from S.S. 304 Grade.
Lid (single piece door) made of stainless steel tightened by Radial Locking System.
Sealing of Lid by Neoprene Rubber Gasket
Chamber Insulated by Mineral/Glass Wool to minimise the heat losses and is covered by polished stainless steel sheet.
Fitted with pressure gauge, safety valve and steam release valve.
Sterilizing Temperature up to 1340C.
Sterilizing pressure : 1.2 to 1.5 kg/cm2 (15 psi to 22psi)
Hydraulically Tested up to 40 psi.
These Autoclaves work on the principle of downward displacement of air which is the most economical method of obtaining sterilization
Fitted with separate valves for injecting the steam into the main chamber.
Fitted with Automatic Vacuum Breaker to break the vacuum in case of formation of vacuum due to steam condensation.
Fitted with Automatic Low Water Level Cut-off Device for Prevention of Heaters.
Fitted with Automatic Pressure Control Switch to economizes power consumption by reducing frequent opening of the steam release valve. It cuts off the power supply to heaters when the set pressure is achieved and re-energizes the heating elements when pressure falls below the set point.
Fitted with Dial thermometer to indicate the inner chamber temperature.
Select EMI as your payment option at the time of payment.
Final EMI is calculated on the total value of your order at the time of payment.
The Bank charges annual interest rates according to the reducing monthly balance. In the monthly reducing cycle, the principal is reduced with every EMI and the interest is calculated on the outstanding balance.
The is no minimum order value to avail the EMI payment option.
While you will not be charged a processing fee for availing ShakeDeal’s EMI option, the interest charged by the bank shall not be refunded by ShakeDeal.
You may check with the respective bank/issuer on how a cancellation, refund or pre-closure could affect the EMI terms, and what interest charges would be levied on you for the same.
For select banks, the interest amount on the first EMI will be calculated from the loan booking date till the payment due date.